Compact Manually Operated System & RS 232 Data Output.
Stiff and Low Dead Volume Components for constant System Volume during Pressure Cycles.
100psig or 200psgi Helium Charge Pressure in Reference Volumes ( Vr) (specify pressure with order).
Micro and Small Size Cup for Cuttings and Unconsolidated Grains Supplied with Handling Tools.
Large range sample size accommodated from cuttings, via Ø1.13”(28.8mm ) x 4” (101.6mm) to Ø1.63” (41.5mm ) x 4” (101.6mm). i.e.. Unconsolidated Cores with Teflon heat shrink.
High Tensile St. St. Matrix Cup with Air Gap below Nylon Liner Insulation.
Graded Volume High Accuracy Calibrated High Tensile Stainless St. Pack-out Billets in carrying case.
Helium Leak Tight ¼ Turn Diaphragm Valves.
3 Reference Volumes (Vr-A, B & C ).
Replaceable Sintered Stainless Steel Filters in 3 Places to Protect Valve Integrity.
High Degree of Insulation to Reference Volumes and Pressure Transducer.
Easy Access to all Sites for Leak Checking and Repair.
Ø ¼” Copper Coil for Fast Vr Pressure Charge up and Temperature Equilibration.
SENSORS AND GAUGES:
Pressure Transducer: Accuracy (Combined effects of Non-linearity, Hysteresis and Repeatability) +/- 0.04 % FS BSL (maximum).
Panel Meter: 6 digits with RS 232 to Data Acquisition Module and Reduction/Analysis Program.
Gas Temperature : PT 100 Grade A 0.1°C accuracy and 0.01°C resolution.
SERVICE REQUIREMENTS:
Standard Unit Process Gas: Regulated Helium Gas to 100 psig (7barg) or 200psig (14barg) (maximum).
Optional Model Process Gas: Helium Gas to 3000psig (207barg) (maximum) to inlet port connector.
Matrix Cup Loading Frame Actuator Pressure: 145 psig (10barg) compressed air (Caution! Must be set to this Value for on Gauge Safe Operation.
PHYSICAL DATA:
Power Supply: 240 Vac, 50 Hz, 1Ph.
Dimensions (Standard Unit): 430 mm x 250 mm x 200 mm
ErgoTech
Unit 3 Cae Ffwt Business Park Glan Conwy Conwy
LL28 5SP UK
This drawing is copyright (c) and the associated procedure is the property of ErgoTech. It is issued confidentially to parties interested in acquiring the process and to authorised/licensed clients using it. The drawing is not to be reproduced or circulated by any parties without the written consent of ErgoTech which will not be unduly withheld. The drawing must not be mounted on any display boards or reproduced in reports without the written consent of ErgoTech. When permission is granted the reproduction must be identical to the original and the ownership of the drawing and the process embodied acknowledged to ErgoTech by displaying "ErgoTech (c)"